Specs at a glance
- 
                              Accuracyclass B acc. to IEC 60751 
 class A acc. to IEC 60751
 class AA acc. to IEC 60751
- 
                              Response timedepending on configuration 
 iTHERM QuickSens: t90 = 1,5 s
 iTHERM StrongSens: t90 = 9,5 s
- 
                              Max. process pressure (static)at 20 °C: 40 bar (580 psi) 
- 
                              Operating temperature rangePT100 WW: 
 -200 °C … 600 °C
 (-328 °F … 1.112 °F)
 iTHERM StrongSens:
 -50 °C … 500 °C
 (-58 °F … 932 °F)
 iTHERM QuickSens:
 -50 °C … 200 °C
 (-58 °F … 392 °F)
 PT100 TF:
 -50 °C … 200 °C
 (-58 °F … 392 °F)
- 
                              Max. immersion length on request48" 
Field of application
It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
- Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries 
- Measuring range: –200 to +600 °C (–28 to +1 112 °F) 
- Pressure range up to 40 bar (580 psi) 
- Protection class: up to IP69K 
Benefits
-  User-friendly and reliable from product selection to maintenance 
-  iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values 
-  iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control 
-  iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety 
-  iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration 
-  iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating 
-  International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability 
Extended selection
- 
        High-end products 
- Highly functional and convenient
Technical excellence
Simplicity
 
                              - 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity | 
|---|---|---|
| 
 Fundamental selection Meet your basic measurement needs | Technical excellence | Simplicity | 
| 
 Lean selection Handle your core processes easily | Technical excellence | Simplicity | 
| 
 Extended selection Optimize your processes with innovative technologies | Technical excellence | Simplicity | 
| 
 Xpert selection Master your most challenging applications | Technical excellence | Simplicity Variable | 
Predecessor
- 
                        - 
                                                            Technical Information (TI)
 TI Weld-in adapter, process adapter and flangesLevel, pressure and temperature measurement EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language: English Version: 06/12/2024 File size: 1.3 MB File name: TI00426FEN_2624.pdf 
- 
                                                            
- 
                        - 
                                                            Technical Information (TI)
 TI iTHERM ModuLine TM412 Hygienic modular thermometerImperial RTD thermometer with or without thermowell for hygienic applications EN 31/08/202510/04/202401/08/202214/01/202131/10/2018Language: English Version: 31/08/2025 File size: 2.7 MB File name: TI01348TEN_0725-00.pdf 
- 
                                                            
- 
                        - 
                                                            Operating Instruction (BA)
 BA Modular hygienic thermometersUniversal modular thermometers with RTD insert for hygienic applications EN 31/08/202520/01/2020Language: English Version: 31/08/2025 File size: 1 MB File name: BA02023TEN_0225-00.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 Installation Instructions iTHERM TM402, TM412Imperial hygienic RTD thermometer Language: English Version: 04/07/2017 File size: 821.1 KB File name: EA01221T09EN_0117.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 XA TR1x, Tx88, TSx310, Tx6x, TC1x, TPx100, TM411, TR24Thermometers and inserts 
 Ex ia IIC T1...T6 Ga
 Ex ia IIIC T<sub>200</sub> 85 °C...T<sub>200
 </sub> 450 °C DaEN 30/08/202315/05/202331/07/2020Language: English Version: 30/08/2023 File size: 474.5 KB File name: XA02109TEN_0323-00.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 XA iTHERM TM411Modular RTD assemblies for hygienic applications 
 0Ех ia IIC T6…T1 Ga Х
 Ga/Gb Ех ia IIC T6…T1 Х
 Еx ia IIIC T85°C…T450°C Da Х
 Еx ia IIIC T85°C…T450°C Da/Db ХEN 10/07/202429/10/2021Language: English Version: 10/07/2024 File size: 434.8 KB File name: XA02760TEN_0224-00.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 XA iTHERM TM211, TPx100, TSx310RTD/TC inserts and cable thermometers 
 ATEX/IECEx:
 Ex ia IIC T6 Ga
 Ex ia IIC T6 Ga/Gb
 Ex ia IIIC Txxx °C DaEN 30/03/202318/07/202210/07/201928/11/201628/11/2012Language: English Version: 30/03/2023 File size: 456.3 KB File name: XA00100REN_1823-00.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 TM411, TM412Control Drawing 
 FM IS, NIEN 15/06/201801/12/2014Language: English Version: 15/06/2018 File size: 79.3 KB File name: XA01150TEN_0218.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 XA iTHERM TM411, TM412Modular RTD assemblies for hygienic applications 
 ATEX, IECEx:
 Ex ia IIIC Txxx °C Da/Db
 Ex ia IIC T6 Ga/GbEN 27/03/202330/06/202207/05/201808/11/2012Language: English Version: 27/03/2023 File size: 441 KB File name: XA01024TEN_0423-00.pdf 
- 
                                                            
- 
                        - 
                                                            Ex Safety Instruction (XA)
 XA TRxx, TCxxRTD/TC thermometers 
 Ga/Gb Ех ia IIC T6…T1 Х
 Ех ia IIIC T85 °C…T450 °C Da/Db ХEN 17/07/202410/03/202002/11/2016Language: English Version: 17/07/2024 File size: 453.6 KB File name: XA01459TEN_0324-00.pdf 
- 
                                                            
 
                                             
                                     
                                     
                                     
                                     
                                     
                                     
                                     
                                     
                   
                  