T54
Explosion proof TC thermometer, US style

©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.

Ce produit n'est pas disponible pour ce marché

  • Avantages

    • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

    • Remove and install...

  • Domaine d'application

    The sensor assembly can be used in process industries such as:

    • Chemicals

    • Petrochemical

    • Refineries

    • Offshore Platforms

Caractéristiques et spécifications

Retour

Details

  • Principe de mesure

    Thermocouple

  • Caractéristiques / Applications

    Style US antidéflagrant

    Capteur de température modulaire

    Pour applications à fortes contraintes

    Raccord process à bride

    avec extension

    y compris protecteur

  • Tête de raccordement

    TMT162 - aluminium - boîtier de terrain avec ou sans affichage

    TMT162 - inox - boîtier de terrain avec ou sans affichage

    TMT142 - aluminium - boîtier de terrain avec ou sans affichage

    TA30H - aluminium - boîtier de terrain avec ou sans affichage

  • Protecteur / tube de protection

    Foré dans la masse

  • Insert / Sonde

    à isolation minérale (MI), flexible

  • Diamètre extérieur tube de protection / insert

    7/8'' (22,23 mm)

    17/16'' (26,99 mm)

  • Longueur dʹimmersion sur demande

    jusqu'à 571 mm (22.5")

    autres sur demande

  • Matériau tube de protection/protecteur

    316/316L

    sur demande

  • Revêtement en option

    Disponible sur demande

  • Raccord process

    Bride :

    ASME 1" 150 RF (B16.5)

    ASME 1" 300 RF (B16.5)

    ASME 1" 600 RF (B16.5)

    ASME 1,5" 150 RF (B16.5)

    ASME 1,5" 300 RF (B16.5)

    ASME 1,5" 600 RF (B16.5)

    ASME 2" 150 RF (B16.5)

    ASME 2" 300 RF (B16.5)

    ASME 2" 600 RF (B16.5)

  • Forme de lʹextrémité

    Droite

    Rétreinte

  • Rugosité de surface Ra

    0,80 µm (32 μin)

  • Gamme de temperature de service

    Type T :

    -270 °C ...370 °C

    (-454 °F ...698 °F)

    Type J :

    -210 °C ...720 °C

    (-346 °F ...1.328 °F)

    Type E :

    -270 °C ...820 °C

    (-454 °F ...1.508 °F)

    Type K :

    -270 °C ... 1.150 °C

    (-454 °F ...2.102 °F)

    Type N :

    -270 °C ... 1.150 °C

    (-454 °F ...2.102 °F)

  • Pression process max. (statique)

    à 20 °C : 500 bar (7.252 psi)
    dépend de la configuration

  • Précision

    Standard selon ASTM E-230

    Spécial selon ASTM E-230

  • Temps de réponse

    Selon la configuration

    63% rt = 15 s

  • Intégration transmetteur en tête

    oui (4 … 20 mA ; HART ; Profibus PA ; Foundation Fieldbus)

  • Agrément Ex

    FM XP

    CSA XP

    FM/CSA XP

    CSA GP

  • Certification

    SIL (uniquement transmetteur)

Documents / Manuels / Logiciels

Accessoires / pièces de rechange

Nr
Order code
Specification