Specs at a glance
-
Measuring range
-1500 mV - +1500 mV
-
Process temperature
-15°C - 135°C
-
Process pressure
max. 16bar
Field of application
Ceragel CPS72 is the analog specialist for ORP measurement in sterile and hygienic applications. Its state-of-the-art gel is poison resistant and guarantees stable measurement even in flowing media or low conductivity. The sensor is sterilizable, autoclavable and non-toxic assuring highest safety of your products.
Hygienic and sterile applications:
- Fermenters
- Biotechnology
- Life sciences
- Food industryProcess technology and monitoring of processes with:
- Quickly changing pH values
- High proportion of electrode poisons such as H2S
With ATEX, FM, and CSA approval for application in hazardous areas
Benefits
Suitable for CIP/SIP cleaning and autoclaving maintaining high accuracy
Sensor resists strong acids and bases and high organic loads
Certified biocompatibility, no cytotoxicity
Free from animal-based materials and from acrylamide
Predecessor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Ceragel CPS71D and CPS71 Technical Information
pH single-rod measuring cells, analog or with digital Memosens
technologyEN 14/09/201519/12/201201/10/200501/03/200401/09/2002Language:
English
Version:
14/09/2015
File size:
457.9 KB
File name:
TI00245CEN_1515.pdf
-
-
-
Technical Information (TI)
Technical Information Ceragel CPS72 and CPS72D
ORP electrodes, analog anddigital with Memosens
technology
For process technology, hygienic and sterile applications
with poison-resistant reference with ion trapEN 28/07/201401/05/200501/07/2003Language:
English
Version:
28/07/2014
File size:
407.6 KB
File name:
TI00374CEN_1313.pdf
-
-
-
Operating Instruction (BA)
pH/ORP sensors and reference half cells
Sensors with Memosens technology and analog sensors
EN 04/05/202031/12/201730/11/2015Language:
English
Version:
04/05/2020
File size:
1.1 MB
File name:
BA01572CEN_0320.pdf
-
-
-
Ex Safety Instruction (XA)
Analog pH/ORP sensors
pH/ORP measurement
Supplement to BA01572C, BA02056C
Safety instructions for electrical apparatus in explosion-hazardous
areas
ATEX II 1G Ex ia IIC T3/T4/T6 GaEN 21/10/202101/10/200802/11/200301/07/200301/07/2002Language:
English
Version:
21/10/2021
File size:
493.2 KB
File name:
XA00028CEN_1121.pdf
-
-
-
Ex Safety Instruction (XA)
Analog ph/ORP sensors Temperature probe CTS1
pH/ORP measurement
Supplement to BA01572C, BA02056C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UKEx II 1 G Ex ia IIC T3/T4/T6 GaLanguage:
English
Version:
08/12/2021
File size:
427.3 KB
File name:
XA02785CEN_0121-00.pdf
-
-
-
Ex Safety Instruction (XA)
Analog pH/ORP sensors
pH and ORP measurement
Supplement to BA01572C
Safety instructions for electrical equipment in explosion-hazardous
areas
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex ia IIC T4/T6 GaX
EAC Ex 1Ex ib IIC T3/T4/T6 Gb XEN 01/03/202218/02/202121/03/2016Language:
English
Version:
01/03/2022
File size:
484.5 KB
File name:
XA01440CEN_0322-00.pdf
-
-
-
Special Documentation (SD)
Kurzanleitung pH-/Redox-Sensoren - Short Instructions pH/ORP sensors
pH-/Redox-Sensoren - pH/ORP sensors
EN 01/04/200701/09/1999Language:
English
Version:
01/04/2007
File size:
361.7 KB
File name:
SD050Ca2.pdf
-
-
-
EU Declaration
Product family: CeraGel, CeraLiquid, CeraTex, OrbiPore, OrbiSint, OrbiTex, Sensor
Product root: CPS11-, CPS12-, CPS13-, CPS21-, CPS31-, CPS41-, CPS42-, CPS43-, CPS64-, CPS71-, CPS72-, CPS91-, CPS92-, CTS1-
Declaration number: EC_00624_04.24EN 18/10/2024Language:
English
Version:
18/10/2024
File size:
227.6 KB
File name:
EC_00624_04.24_CPSxx_Ex_.pdf
-
-
-
EU Declaration
Product family: CeraGel, CeraLiquid, CeraTex, NoryLab, OrbiPore, OrbiSint, OrbiTex, Sensor, TopHit
Product root: CPS11-, CPS12-, CPS13-, CPS21-, CPS31-, CPS41-, CPS42-, CPS43-, CPS441-, CPS471-, CPS491-, CPS51-, CPS52-, CPS64-, CPS
65-, CPS71-, CPS72-, CPS91-, CPS92-
Declaration number: EU_00921_02.23EN 09/01/2023Language:
English
Version:
09/01/2023
File size:
276.3 KB
File name:
EU_00921_02.23 CPS nonEx.pdf
-
-
-
UK Conformity Assessed
Product family: CeraGel, CeraLiquid, CeraTex, OrbiPore, OrbiSint, OrbiTex, Sensor
Product root: CPS11-, CPS12-, CPS31-, CPS41-, CPS71-, CPS72-, CPS91-, CTS1-
Declaration number: UK_00442_01.21Language:
English
Version:
25/10/2021
File size:
292.5 KB
File name:
UK_00442_01.21_CPSxx Ex.pdf
-