Specs at a glance
Accuracy
class 2 acc. to IEC 60584
Max. process pressure (static)
Operating temperature range
Type S: 0 °C ...1.600 °C (32 °F ...2.912 °F) Type R: 0 °C ...1.600 °C (32 °F ...2.912 °F) Type B: 600 °C ...1.700 °C (1.112 °F ...3.092 °F)
Max. immersion length on request
up to 3.500,00 mm (137,80'')
Field of application
Measuring points with extremely high process temperatures require these thermometers with ceramic thermowells and special metal thermocouples, such as platinum and rhodium. The thermowell as well as the intermediate and internal sheath of ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
The TAF12T are assemblies with triple ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.
Process temperatures: up to +1700 °C (+3092 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
Long term stable measurement due to sensor protection with non-porous materials
Flexible product selection by modular design
Optimized life cycle costs by means of replaceable spare parts
Extended selection
High-end products
Highly functional and convenient
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Characteristic / Application
metric style modular temperature assembly high temperature (furnace) ncl. triple ceramic thermowell
Thermowell / protection tube
ceramic protection tube and 2x inner tube
Outer diameter protection tube / Insert
24,0 mm (0,94") 26,0 mm (1,02")
Max. immersion length on request
up to 3.500,00 mm (137,80'')
Material protection tube/ thermowell
Process connection
compression fitting: G11/2"
Operating temperature range
Type S: 0 °C ...1.600 °C (32 °F ...2.912 °F) Type R: 0 °C ...1.600 °C (32 °F ...2.912 °F) Type B: 600 °C ...1.700 °C (1.112 °F ...3.092 °F)
Max. process pressure (static)
Accuracy
class 2 acc. to IEC 60584
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Most downloaded
High temperature thermometers TAF11, TAF12x
English version - 01/2020
Unwrapping the safety seal for flanged ceramic thermometers
Language:
English
Version:
20/01/2020
File size:
125 KB
File name:
EA01291TA2_0120.pdf
19 documents
Omnigrad S TAF11, TAF12x, TAF16
Technical information
High temperature assemblies With metal or ceramic thermowells Adjustable process connection Thermocouple sensor types J, K, N, R, S, B
EN
German Spanish French Croatian Italian Japanese Polish Portuguese Russian Chinese
12/11/2013
25/01/2012
16/06/2011
01/09/2004
Language:
English
Version:
12/11/2013
File size:
543.4 KB
File name:
TI00251ten_1413.pdf
KA Safe unpacking of ceramic thermowells
iTHERM FlameLine TAF1x high-temperature thermometer
EN
German Spanish French Italian Portuguese Russian Chinese
25/03/2024
Language:
English
Version:
25/03/2024
File size:
351.9 KB
File name:
KA01698TEN_0124-00.pdf
High temperature thermometers TAF11, TAF12x
Unwrapping the safety seal for flanged ceramic thermometers
EN
German French Chinese
20/01/2020
Language:
English
Version:
20/01/2020
File size:
125 KB
File name:
EA01291TA2_0120.pdf
Technical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
Thermometer und Transmitter für die Prozessindustrie
Language:
German
Version:
17/05/2023
File size:
17.9 MB
File name:
FA00006Tde_2223_online.pdf
Misura della temperatura Termometri e trasmettitori per l'industria di processo
Language:
Italian
Version:
09/07/2024
File size:
20.3 MB
File name:
FA00006Tit_2223.pdf
Thermometers and transmitters for the process industry
Language:
English
Version:
17/05/2023
File size:
18 MB
File name:
FA00006Ten_2223_online.pdf
Capteurs et transmetteurs de température pour les industries de process
Language:
French
Version:
20/12/2019
File size:
60.9 MB
File name:
FA00006TFR-Mesure de temperature.pdf
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Language:
Spanish
Version:
20/04/2018
File size:
5.5 MB
File name:
FA00006Tes_Catalogo Temperatura_1818.pdf
Termometri e trasmettitori per l'industria di processo
Language:
Italian
Version:
17/02/2020
File size:
30.6 MB
File name:
FA00006TIT_2020.pdf
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Extension cable TC IEC 2x type S/R,3pcs.
Extension cable TC IEC 2x type B, 3 pcs.
Terminal head only on request
Spare parts kit sealing TA30A/TA30D
Fixing kit cpl.TMT82/85/84 (european)
iTEMP TMT181, Head Transmitter PCP
Drawing number
Order code
B
TMT181-
iTEMP TMT84, Transmitter PA
Drawing number
Order code
B
TMT84-
iTEMP TMT85, Transmitter FF
Drawing number
Order code
B
TMT85-
Readwin 2000 Operation + Read. software
iTEMP TMT182, Head Transmitter HART
Drawing number
Order code
B
TMT182-
iTEMP TMT82, Transmitter HART
Drawing number
Order code
B
TMT82-
Stop Flange adjustable,DIN EN 50446,34mm
Drawing number
Order code
C
60000517
Compression fitting G1 1/2", 35mm
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all