Specs at a glance
-
Accuracy
class 1 acc. to IEC 60584
-
Response time
depending on configuration
t50 = 6 s
t90 = 13 s -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Operating temperature range
Type K:
-40 °C ...1.100 °C
(-40 °F ...2.012 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F) -
Max. immersion length on request
up to 10.000,00 mm (393,70'')
Field of application
The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Universal range of application
Measuring range: -40 to 1100 °C (-40 to 2012 °F)
Pressure range up to 40 bar (580 psi)
Degree of protection: up to IP68
Benefits
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
High degree of insert compatibility and design as per DIN 43772
Fast response time with reduced/tapered tip form
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA)
Head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Technical information TC 12, Omnigrad M
Technical information TC 12, Omnigrad M thermocouple thermometer, cylindrical thermometer
EN 01/02/2004Language:
English
Version:
01/02/2004
File size:
770.9 KB
File name:
TI275ten_0204.pdf
-
-
-
Technical Information (TI)
Omnigrad M TR12, TC12
Modular thermometer, with optional RTD or TC insert
EN 05/06/201913/06/2013Language:
English
Version:
05/06/2019
File size:
1.1 MB
File name:
TI01118TEN_0219.pdf
-
-
-
Ex Safety Instruction (XA)
TR1x, TR4x, TR88, TSC310, TST310, TR6x, TC1x, TC6x, TC88, TPC100, TPR100, TM411, TM412, TR24
Thermometers and inserts Ex iaIIC T1-T6 Ga, Ex iaD 20 T85-T450
EN 31/07/2020Language:
English
Version:
31/07/2020
File size:
175.2 KB
File name:
XA02109TEN_0120.pdf
-
-
-
Ex Safety Instruction (XA)
Omnigrad TR1x, TR4x, TR88, TR6x, TC1x, TC88, TEC420, TC6x ATEX: II 1D, II 1/2D Ex ia IIIC or II 1G, II 1/2G Ex ia IIC IECEx: Ex iaIIC Safety Instructions
Safety instructions for electrical apparatus certified for use in explosion-hazardous areas.
EN 03/05/201628/11/201201/06/200901/10/2007Language:
English
Version:
03/05/2016
File size:
945.3 KB
File name:
XA00072RA3_1416.pdf
-
-
-
Ex Safety Instruction (XA)
iTHERM TS111, TM211 Omniset TPx100, Omnigrad TSx310 RTD/TC inserts and cable thermometers ATEX: II1D, II1/2DEx ia IIIC or II1G, II1/2G Ex ia IIC IECEx: Ex ia IIC Ga, Ga/Gb
Safety instructions for electrical apparatus certified for use in explosion-hazardous areas.
EN 10/07/201928/11/201628/11/201210/05/201201/07/2010Language:
English
Version:
10/07/2019
File size:
977 KB
File name:
XA00100RA3_1619.pdf
-
-
-
Ex Safety Instruction (XA)
TR10, TR11, TR12, TR13, TC10, TC12, TC13
Modular RTD/TC assemblies ATEX: II 1/2D Ex ta/tb IIIC T85 °C...T450 °C Da/Db IECEx: Ex ta/tb IIIC T85 °C...T450 °C Da/Db Safety instructions for electrical apparatus in explosion-hazardous areas
EN 09/05/202207/05/201820/10/201625/10/2012Language:
English
Version:
09/05/2022
File size:
422.6 KB
File name:
XA01057TEN_0422-00.pdf
-
-
-
Ex Safety Instruction (XA)
RTD/TC thermometers TRxx, TCxx, TEC420, TS111, TM211, TM41x, TPx100, TSx310, TM1x1
ATEX: II 3G Ex nA IIC T6...T1 Gc II 3D Ex tc IIIC T85°C...T450°C Dc Safety instructions for electrical apparatus inexplosion-hazardous areas
EN 14/03/202223/05/201904/08/201716/02/201526/02/2013Language:
English
Version:
14/03/2022
File size:
454.2 KB
File name:
XA00044REN_1822-00.pdf
-
-
-
Ex Safety Instruction (XA)
Omnigrad TRxx, TCxx, TxCxxx
RTD/TC modular thermometers 0Ех ia IIC T6…T1Ga Х Ga/Gb Ех ia IIC T6…T1 Ga Х Ех ia IIIC 85 °C…450 °C Da Х Ех ia IIIC 85 °C…450 °C Da/Db Х
EN 10/03/202002/11/2016Language:
English
Version:
10/03/2020
File size:
171.9 KB
File name:
XA01459TEN_0220.pdf
-
-
-
Fields of Activities (FA)
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Language:
German
Version:
17/02/2020
File size:
5.8 MB
File name:
FA00006Tde_2020.pdf
-
-
-
Fields of Activities (FA)
Temperature measurement
Thermometers and transmitters for the process industry
EN 03/05/2022Language:
English
Version:
03/05/2022
File size:
47.5 MB
File name:
FA00006Ten_2122.pdf
-